Helm Compounds

Transparency

Every batch, on the record.

Every line item on every purchase order is tested. Not a sample of the shipment. Not one certificate stretched across several doses.

Each batch gets its own lot number and its own test, every time. A batch that misses a threshold is not sold, and the lot is withdrawn rather than reworked or blended into another.

7
Lots released
0
In testing
6
Compounds
2
Independent labs

By compound

Certificates by compound

Each compound has its own page of lot-matched HPLC results. A compound with no laboratory report on file yet says so on its page.

Look up a lot

Enter the lot code printed on the label. Case, spaces and dashes don't matter.

Record

Every lot, every result

  • CJC-1295/IPAMORELIN 10MGHLM-Y2BHDDPurity99.87%Content10.08 / 10.00 mgIdentityConfirmedCurrent
    Lot
    HLM-Y2BHDD
    Tested
    Oct 17, 2026
    Vials tested
    1 vial (1 of 50 received; 49 released)
    Lab
    Freedom Diagnostics Testing
    Lab report no.
    2610150533
    Method
    HPLC + MS
    Identity
    Confirmed
    Purity
    99.87%
    Potency
    —
    Source
    Helm commissioned

    COA 2610150533. Search code Helm2610150533. Verify at FreedomDiagnosticsTesting.com. Identity (LC-MS): Ipamorelin / CJC-1295, confirmed. Net content by component: Ipamorelin 5.13 mg, CJC-1295 4.95 mg. Total 10.08 mg against a 10 mg label. Appearance: white lyophilized powder.

    File fingerprint (SHA-256)

    a5517667a75f9bdde88bbb2d95ebb3209380ec7f0d5027d8d92ea24fb36edb48

    Hash the downloaded PDF and compare. If it matches, the file is byte-for-byte the one published here.

    View certificate
    Compound
    CJC-1295/IPAMORELIN 10MG
    Labelled mg
    10.00 mg
    Measured purity
    99.87%
    Net content
    10.08 mg
    Lab
    Freedom Diagnostics Testing
    Test date
    Certificate of analysis (PDF)
  • KLOW 80MGHLM-6GM5PWPurity99.85%Content81.39 / 80.00 mgIdentityConfirmedCurrent
    Lot
    HLM-6GM5PW
    Tested
    Oct 17, 2026
    Vials tested
    1 vial (1 of 40 received; 39 released)
    Lab
    Freedom Diagnostics Testing
    Lab report no.
    2610150532
    Method
    HPLC + MS
    Identity
    Confirmed
    Purity
    99.85%
    Potency
    —
    Source
    Helm commissioned

    COA 2610150532. Search code Helm2610150532. Verify at FreedomDiagnosticsTesting.com. Identity (LC-MS): GHK-Cu / KPV / TB-500 / BPC-157, confirmed. Net content by component: GHK-Cu 55.51 mg, KPV 10.79 mg, TB-500 7.64 mg, BPC-157 7.45 mg. Total 81.39 mg against an 80 mg label. Appearance: blue lyophilized powder.

    File fingerprint (SHA-256)

    9fcef918631ba691979113851ff3320320b339c93cf0353d9ed81740215ee5a8

    Hash the downloaded PDF and compare. If it matches, the file is byte-for-byte the one published here.

    View certificate
    Compound
    KLOW 80MG
    Labelled mg
    80.00 mg
    Measured purity
    99.85%
    Net content
    81.39 mg
    Lab
    Freedom Diagnostics Testing
    Test date
    Certificate of analysis (PDF)
  • HLM-GGG (30mg)HLM-Z2Q8JJPurity99.85%Content27.72 / 30.00 mgIdentityConfirmedCurrent
    Lot
    HLM-Z2Q8JJ
    Tested
    Oct 17, 2026
    Vials tested
    1 vial (1 of 70 received; 69 released)
    Lab
    Freedom Diagnostics Testing
    Lab report no.
    2610150530
    Method
    HPLC + MS
    Identity
    Confirmed
    Purity
    99.85%
    Potency
    —
    Source
    Helm commissioned

    COA 2610150530. Search code Helm2610150530. Verify at FreedomDiagnosticsTesting.com. Identity (LC-MS): Retatrutide, confirmed. Appearance: white lyophilized powder.

    File fingerprint (SHA-256)

    d6d4be90505ac6739158aa56abd1e484a2fa6bcdeca2dc995f4db7d7e42b1862

    Hash the downloaded PDF and compare. If it matches, the file is byte-for-byte the one published here.

    View certificate
    Compound
    HLM-GGG (30mg)
    Labelled mg
    30.00 mg
    Measured purity
    99.85%
    Net content
    27.72 mg
    Lab
    Freedom Diagnostics Testing
    Test date
    Certificate of analysis (PDF)
  • HLM-GGG (10mg)HLM-9SDB9CPurity99.91%Content10.46 / 10.00 mgIdentityConfirmedCurrent
    Lot
    HLM-9SDB9C
    Tested
    Oct 17, 2026
    Vials tested
    1 vial (1 of 50 received; 49 released)
    Lab
    Freedom Diagnostics Testing
    Lab report no.
    2610150529
    Method
    HPLC + MS
    Identity
    Confirmed
    Purity
    99.91%
    Potency
    —
    Source
    Helm commissioned

    COA 2610150529. Search code Helm2610150529. Verify at FreedomDiagnosticsTesting.com. Identity (LC-MS): Retatrutide, confirmed. Appearance: white lyophilized powder.

    File fingerprint (SHA-256)

    8bcd83f240779cea0469341922c59534adc6579ba0326a34353a6e7e8a29bc7e

    Hash the downloaded PDF and compare. If it matches, the file is byte-for-byte the one published here.

    View certificate
    Compound
    HLM-GGG (10mg)
    Labelled mg
    10.00 mg
    Measured purity
    99.91%
    Net content
    10.46 mg
    Lab
    Freedom Diagnostics Testing
    Test date
    Certificate of analysis (PDF)
  • MOTS-C (10mg)HLM-P7ZTKPPurity99.35%Content10.83 / 10.00 mgIdentityConfirmedCurrent
    Lot
    HLM-P7ZTKP
    Tested
    Sep 26, 2026
    Vials tested
    1 vial from the 500-vial lot
    Lab
    Freedom Diagnostics Testing
    Lab report no.
    2609240148
    Method
    HPLC + MS
    Identity
    Confirmed
    Purity
    99.35%
    Potency
    —
    Source
    Helm commissioned

    Freedom Diagnostics Testing, Franklin TN. Accession 2609240148 / search code Helm2609240148. Received 2026-09-24, reported 2026-09-26. Appearance: white lyophilized powder. Vendor lot designation: Red Cap. Signed by Alex Johnson, Principal Chemist.

    File fingerprint (SHA-256)

    26b1d0530114a22b35b1aef13228851d88b2abfb2a0efe784e9ab1f1f2d498ed

    Hash the downloaded PDF and compare. If it matches, the file is byte-for-byte the one published here.

    View certificate
    Compound
    MOTS-C (10mg)
    Labelled mg
    10.00 mg
    Measured purity
    99.35%
    Net content
    10.83 mg
    Lab
    Freedom Diagnostics Testing
    Test date
    Certificate of analysis (PDF)
  • BPC-157 (10mg)HLM-V5WV98Purity99.88%Content10.35 / 10.00 mgIdentityConfirmedCurrent
    Lot
    HLM-V5WV98
    Tested
    Sep 21, 2026
    Vials tested
    1 vial (1 of 90 received; 89 released)
    Lab
    Freedom Diagnostics Testing
    Lab report no.
    2609180465
    Method
    HPLC + MS
    Identity
    Confirmed
    Purity
    99.88%
    Potency
    —
    Source
    Helm commissioned

    Freedom Diagnostics report received 2026-09-21. Supplier lot description: Red Cap. Appearance: white lyophilized powder. One vial was consumed by testing and written off. Sterility, endotoxin, and heavy metals were not reported on this certificate.

    File fingerprint (SHA-256)

    0c0f227dbd0459dfcfd6247b23949035dfd5ec86dccc76e5ced493c9f3496297

    Hash the downloaded PDF and compare. If it matches, the file is byte-for-byte the one published here.

    View certificate
    Compound
    BPC-157 (10mg)
    Labelled mg
    10.00 mg
    Measured purity
    99.88%
    Net content
    10.35 mg
    Lab
    Freedom Diagnostics Testing
    Test date
    Certificate of analysis (PDF)
  • HLM-GGG (30mg)HLM-TXXR9JPurity98.39%Content30.61 / 30.00 mgIdentityConfirmedCurrent
    Lot
    HLM-TXXR9J
    Tested
    Aug 17, 2026
    Vials tested
    3mL sample
    Lab
    ILS Laboratories
    Lab report no.
    COA-2026-1JISWU
    Method
    RP-HPLC
    Identity
    Confirmed
    Purity
    98.39%
    Potency
    —
    Source
    Helm commissioned

    COA #COA-2026-1JISWU. Access code TPXM8BKD. Verify: portal.ils-lab.com. Identity (HPLC-RTM): Retatrutide, Confirmed - PASS. Fentanyl Screen (immunoassay, 50 ng/mL cutoff): Not Detected - PASS. Net Peptide Content: 30.61 mg (reported, not a certified potency %).

    File fingerprint (SHA-256)

    ce4b8f6bca13d610ac5cf6968a48570b03e2024710a05b7f082c6f9a46bff31f

    Hash the downloaded PDF and compare. If it matches, the file is byte-for-byte the one published here.

    View certificate
    Compound
    HLM-GGG (30mg)
    Labelled mg
    30.00 mg
    Measured purity
    98.39%
    Net content
    30.61 mg
    Lab
    ILS Laboratories
    Test date
    Certificate of analysis (PDF)

Standards

What a lot has to clear

These are the thresholds each batch is measured against before it is released. Material that misses one is not sold, and it appears above with the value it hit.

Every line item on every order is tested for identity, purity and content. Contamination testing (endotoxin, sterility) is not part of the standing panel today, and nothing on this page claims otherwise.

Identity

HPLC

Must match the declared compound

Confirms the vial contains what the label says. Purity alone cannot establish this: a sample can be 99% pure and 100% the wrong molecule.

Purity

HPLC

≥ 98.0%

How much of the material is the target compound rather than related impurities.

Quantitation

HPLC

Measured against label claim

How many milligrams are actually in the vial, reported beside what the label claims. Under-fill is the most common substantiated complaint in this market.

Our side of it

If we are wrong, we make it right

Purity guarantee

If an independent certificate from a named laboratory shows a released lot below the purity threshold published above, we replace it or issue store credit. Send the certificate to support@helmcompounds.com with the lot code and we will confirm it against our own record for that lot.

This sits alongside our refund policy rather than replacing it.

Test it yourself

Send any lot you have bought to an independent laboratory of your choosing and send us the certificate. We publish it here beside our own, whatever it says, flagged as customer submitted, and we credit your account for the cost of the test.

Contact support@helmcompounds.com before sending so we can confirm the lot and the credit.

Provenance

Who runs the tests

Testing is done by outside laboratories, not in-house. Each released lot above lists the lab that tested it and that lab's own report number, so a certificate can be taken back to its source.

ILS Laboratories

San Diego, California

Purity, identity and quantitation by HPLC

ils-lab.com

Freedom Diagnostics Testing

Franklin, Tennessee

Purity by HPLC-UV, identity by LC-MS, and net content

freedomdiagnosticstesting.com

Reference

Frequently asked

Why are there so few lots listed?

Because this page counts batches actually purchased and released, not products in a catalog. Every line item on every order is tested, so a lot appears here only once that specific batch has been bought and sent to the lab. A vendor carrying continuous inventory lists more certificates because they are sampling a pool that gets topped up; each lot here is one batch, tested before release, and when it is gone the next batch is tested fresh.

Do sold-out lots stay on this page?

Permanently. The record of what was released is more useful than a list of what is currently in stock, and removing a lot once it sells would shrink this page every time it did its job.

How do I find the certificate for the vial I have?

Enter the lot code printed on the label in the box at the top of this page. Case, spaces and dashes do not matter.

Can I verify a certificate independently?

Yes. Each released lot lists the testing lab and that lab's own report number, which you can take to the lab directly. Where a file fingerprint is published, you can also confirm the PDF you downloaded is unmodified.

What is each batch tested for?

Identity, purity and quantitation, by HPLC. Identity confirms the material is the declared compound, purity measures how much of it is that compound rather than related impurities, and quantitation measures how many milligrams are in the vial. Contamination testing is not part of the standing panel today, and nothing on this page claims it is.

What does a lot marked 'In testing' mean?

The batch has been received and sent to the lab, and no result has come back yet. It is listed here before the certificate exists so this page reflects what is actually happening rather than only what has already succeeded.

Terms on this page

Certificate of Analysis (COA)
The lab's signed report for one specific batch. It states what was tested, by which method, and what the result was.
Lot
One batch of material. Every Helm lot is a single batch tested before release. When it is gone, the next batch is tested fresh, so a lot code identifies exactly which material you received.
RP-HPLC
Reverse-phase high-performance liquid chromatography. Separates the sample into its components so the share that is the target compound can be measured. This is where the purity percentage comes from.
LC-MS
Liquid chromatography paired with mass spectrometry. Measures molecular weight to confirm identity, which purity alone cannot do. A sample can be 99% pure and 100% the wrong molecule.
Quantitation
The measured mass of the target compound in the vial, reported in milligrams against what the label claims.
SHA-256
A fingerprint of a file. Change one byte and the fingerprint changes completely, so publishing it lets anyone confirm the certificate they downloaded is byte-for-byte the one issued. It proves the file has not been altered since publication. It does not prove the lab issued it, which is what the lab report number is for.

Everything sold by Helm Compounds is supplied for laboratory research use only. Purity above 98.0% is a statement about the material, not a statement about what it may be used for.